Bl-1010, Bl-1011, Bl-1012 – Dell POWEREDGE M1000E User Manual
Page 138

62
Fabric OS Message Reference
53-1001767-01
BL-1010
7
If the message persists, replace the blade.
Severity
CRITICAL
BL-1010
Message
Probable Cause
Indicates that a failover occurred while some hardware changes were being made on the previously
active control processor (CP) (such as changing the domain ID).
Recommended
Action
No action is required. This blade has been reinitialized. Because reinitializing a blade is a disruptive
operation and can stop I/O traffic, you might have to stop and restart the traffic during this process.
Severity
WARNING
BL-1011
Message
with emb-port int. for chip number>, chip int. is disabled. interrupt status=0x Probable Cause Indicates that too many interrupts in the embedded port caused the specified chip to be disabled. Recommended Action Make sure to capture the console output during this process. Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port. Run the systemVerification command to verify that the blade or switch does not have hardware Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, restart or power cycle the switch. If the message persists, replace the blade or the (nonbladed) switch. Severity CRITICAL BL-1012 Message number> port int. is disabled. status=0x be re-enabled in 1 minute.
The probable cause is too many abnormal frames; the chip is disabled to prevent the control
processor (CP) from becoming too busy.
problems. To run this command root access is required.