Or another – Motorola ColdFire MCF5281 User Manual
Page 646

Debug Support
30-28
Freescale Semiconductor
NOTE
DUMP
does not check for a valid address; it is a valid command only when
preceded by
NOP
,
READ
, or another
DUMP
command. Otherwise, an illegal
command response is returned.
NOP
can be used for intercommand padding
without corrupting the address pointer.
The size field is examined each time a
DUMP
command is processed, allowing the operand size to be
dynamically altered.
Command/Result Formats:
15
12
11
8
7
4
3
0
Byte
Command
0x1
0xD
0x0
0x0
Result
X
X
X
X
X
X
X
X
D[7:0]
Word
Command
0x1
0xD
0x4
0x0
Result
D[15:0]
Longword
Command
0x1
0xD
0x8
0x0
Result
D[31:16]
D[15:0]
Figure 30-25.
DUMP
Command/Result Formats
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3