beautypg.com

11 cluster holdtime, 12 cluster heartbeat – Accton Technology ES4626 User Manual

Page 849

background image

849

startup-config

Startup configuration file

nos.img

System file

boot.rom

System startup file

Command mode:

Admin Mode

Instructions:

The commander switch sends the remote upgrade command to the

member switch. The member switch is upgraded and reset. If this command is executed

in a non-commander switch, an error will be displayed.

Example:

In the commander switch sends the remote upgrade command to the member

switch which has mem-id as 10, src-url as ftp: //admin: [email protected]/nos.img and

dst-url as nos.img

Switch#cluster update member 10 192.168.1.2 ftp: //admin: [email protected]/nos.img

nos.img

22.1.3.11 cluster holdtime

Command: cluster holdtime <

second>

no cluster holdtime

Function:

In the commander switch, set holdtime of heartbeat of the cluster; the “no

cluster holdtime

” command restores the default setting.

Parameter:

is the holdtime of heartbeat of the cluster, valid range is 20 to

65535. The holdtime of heartbeat means the maximum valid time of heartbeat packets.

When the heartbeat packets are received again, the holdtime is reset. If no heartbeat

packets are received in the holdtime, the cluster is invalid.

Command mode:

Global Mode

Default:

The holdtime of heartbeat is 80 seconds by default.

Instructions:

In the commander switch, this command is used to set the holdtime of

heartbeat. And this information is distributed to all the member switches. If this command

is executed in a non-commander switch and the value is less than the current holdtime,

the setting is invalid and an error is displayed.

Example:

Set holdtime of heartbeat of the cluster to 100 seconds

Switch(config)#cluster holdtime 100

22.1.3.12 cluster heartbeat

Command: cluster heartbeat

no cluster heartbeat

Function:

In the commander switch, set interval of sending heartbeat packets among the

switches of the cluster; the “no cluster heartbeat” command restores the default setting.