beautypg.com

2 debug gvrp, 3 bridge-ext garp timer hold, 4 bridge-ext garp timer join – Accton Technology ES4626 User Manual

Page 178

background image

178

5.2.3.2 debug gvrp

Command: debug gvrp

no debug gvrp

Function:

Enable the GVRP debugging function: the “ no debug gvrpcommand

disables the function.

Command mode:

Admin Mode

Default:

GVRP debug information is disabled by default.

Usage Guide:

Use this command to enable GVRP debugging, GVRP packet processing

information can be displayed.

Example:

Enable GVRP debugging.

Switch#debug gvrp

5.2.3.3 bridge-ext garp timer hold

Command:bridge-ext garp timer hold <timer-value>

no bridge-ext garp timer hold

Function:

Set the hold timer for GARP; the “ no garp timer hold” command restores the

default timer setting.

Parameter:

is the value for GARP hold timer, the valid range is 100 to

327650 ms.

Command mode:

Interface Mode

Default:

The default value for hold timer is 100 ms.

Usage Guide:

When GARP application entities receive a join message, join message will

not be sent immediately. Instead, hold timer is started. After hold timer timeout, all join

messages received with the hold time will be sent in one GVRP frame, thus effectively

reducing protocol message traffic.

Example: Set the GARP hold timer value of port 1/10 to 500 ms.

Switch(Config-Ethernet1/10)#bridge-ext garp timer hold 500

5.2.3.4 bridge-ext garp timer join

Command: bridge-ext garp timer join <timer-value>

no bridge-ext garp timer join

Function:

Set the join timer for GARP; the “no bridge-ext garp timer join” command

restores the default timer setting.

Parameter:

is the value for join timer, the valid range is 100 to 327650 ms.

Command mode:

Interface Mode

Default:

The default value for join timer is 200 ms.

Usage Guide:

GARP application entity sends a join message after join timer over, other

GARP application entities received the join message will register this message.

This manual is related to the following products: