2 absolute start, 3 access-list(ip extended) – Accton Technology ES4626 User Manual
Page 755
755
Wednesday, Friday and Sunday.
Switch (Config-Time-Range) # periodic Monday Wednesday Friday Sunday 14:30:00 to
16:45:00
18.2.2.2 absolute start
Command:[no]absolute start
Functions:
Define an absolute time-range, this time-range operates subject to the clock
of this equipment.
Parameters:start_time
: start time, HH:MM:SS (hour: minute: second)
end_time : end time, HH:MM:SS (hour: minute: second)
start_data :
start data, the format is, YYYY.MM.DD(year.month.day)
end_data :
end data, the format is, YYYY.MM.DD(year.month.day)
Remark: time-range is one minute per time, so the time error shall be <= one minute.
Command Mode:
Time-range mode
Default:
No time-range configuration
Usage Guide:
Absolute time and date, assign specific year, month, day, hour, minute of
the start, shall not configure multiple absolute time and date, when in repeated
configuration, the latter configuration covers the absolute time and date of the former
configuration.
Examples:
Make configurations effective from 6:00:00 to 13:30:00 from Oct. 1, 2004 to
Jan. 26, 2005.
Switch(config)#Time-range dcn_timer
Switch ( Config-Time-Range) # absolute start 6:00:00 2004.10.1 end 13:30:00 2005.1.26
18.2.2.3 access-list(ip extended)
Command: access-list
{host
[
access-list
[<igmp-type>] [precedence
access-list
{host-destination
[precedence