beautypg.com

3 port-group mode – Accton Technology ES4626 User Manual

Page 156

background image

156

otherwise, the group will be deleted.

Parameters:

is the group number of a port channel from 1 to 8, if

the group number is already exist, an error message will be given. dst-mac performs

load balancing according to destination MAC; src-mac performs load balance according

to source MAC; dst-src-mac performs load balancing according to source and

destination MAC; dst-ip performs load balancing according to destination IP; src-ip

performs load balancing according to source IP; dst-src-ip performs load balancing

according to destination and source IP. If a port group has formed a port-channel, the

load balance setting cannot be modified, please set the load balance mode before

port-channel.

Default:

Switch ports do not belong to a port channel by default; LACP not enabled by

default.

Command mode:

Global Mode

Example:

Creating a port group and setting the default load balance method.

Switch(C

onfig)# port-group 1

Delete a port group.

Switch(C

onfig)#no port-group 1

4.3.3 port-group mode

Command: port-group mode {active|passive|on}

no port-group

Function:

Adds a physical port to port channel, the “no port-group

“ removes specified port from the port channel.

Parameters:

is the group number of port channel, from 1 to 8;

active

enables LACP on the port and sets it in Active mode; passive enables LACP on

the port and sets it in Passive mode; on forces the port to join a port channel without

enabling LACP.

Command mode:

Interface Mode

Default:

Switch ports do not belong to a port channel by default; LACP not enabled by

default.

Usage Guide:

If the specified port group does not exist, a group will be created first to

add the ports. All ports in a port group must be added in the same mode, i.e., all ports

use the mode used by the first port added. Adding a port in “on” mode is a “forced” action,

which means the local end switch port aggregation does not rely on the information of the

other end, port aggregation will succeed as long as there are 2 or more ports in the group

and all ports have consistent VLAN information. Adding a port in “active” or “passive”

mode enables LACP. Ports of at least one end must be added in “active” mode, if ports of

both ends are added in “passive” mode, the ports will never aggregate.