beautypg.com

3 commands for sflow – Accton Technology ES4626 User Manual

Page 111

background image

111

Command

Explanation

Global Mode

sflow agent-address

no sflow agent-address

Configure the source IP address applied by

the sFlow proxy; the “no” form of the

command deletes this address.

3. Configure the sFlow proxy priority

Command

Explanation

Global Mode

sflow priority

no sflow priority

Configure the priority when sFlow receives

packet from the hardware; the “no sflow

priority

” command restores to the default

4. Configure the packet head length copied by sFlow

Command

Explanation

Global Mode

sflow header-len

no sflow header-len

Configure the length of the packet data

head copied in the sFlow data sampling;

the “no” form of this command restores to

the default value.

5. Configure the max data head length of the sFlow packet

Command

Explanation

Interface Mode

sflow data-len

no sflow data-len

Configure the max length of the data

packet in sFlow; the “no” form of this

command restores to the default.

6.

Configure the sampling rate value.

Command

Explanation

Interface Mode

sflow rate { input

| output

}

no sflow rate [input | output]

Configure the sampling rate when sFlow

performing hardware sampling. The “no”

command deletes the rate value.

7. Configure the Sflow statistic sampling interval

Command

Explanation

Interface Mode

sflow counter-interval

no sflow counter-interval

Configure the max interval when sFlow

performing statistic sampling. The “no” form

of this command deletes

2.8.3 Commands for sFlow

This manual is related to the following products: