beautypg.com

Accton Technology ES4626 User Manual

Page 115

background image

115

Parameter:

None

Command Mode:

All Modes

Usage Guide:

This command is used to acknowledge the operation state of sFlow

Switch#show sflow

Sflow version 1.2

Agent address is 172.16.1.100

Collector address have not configured

Collector port is 6343

Sampler priority is 2

Sflow DataSource: type 2, index 194(Ethernet3/2)

Collector address is 192.168.1.200

Collector port is 6343

Counter interval is 0

Sample rate is input 0, output 0

Sample packet max len is 1400

Sample header max len is 50

Sample version is 4

Displayed Information

Explanation

Sflow version 1.2

Indicates the sFlow version is 1.2

Agent address is 172.16.1.100

Address of the sFlow sample proxy is 172.16.1.100

Collector address have not

configured

the sFlow global analyzer address is not configured

Collector port is 6343

the sFlow global destination port is the defaulted 6343

Sampler priority is 2

The priority of sFlow when receiving packets from the

hardware is 2.

Sflow DataSource: type 2,

index 194(Ethernet3/2)

One sample proxy data source of the sFlow is the

interface e3/1 and its type is 2 (Ethernet), the interface

index is 194.

Collector address is

192.168.1.200

The analyzer address of the sampling address of the

E3/1 interface is 192.168.1.200

Collector port is 6343

Default value of the port on E3/1 interface sampling

proxy is 6343.

Counter interval is 20

The statistic sampling interval on e3/1 interface is 20

seconds

Sample rate is input 10000,

output 0

The ingress traffic rate of e3/1 interface sampling proxy

is 10000 and no egress traffic sampling will be

performed

Sample packet max len is 1400 The length of the sFlow group data sent by the e3/1

This manual is related to the following products: