beautypg.com

2 ip igmp immediate-leave, 3 ip igmp last-member-query-interval – Accton Technology ES4626 User Manual

Page 674

background image

674

command cancels the filter condition

Parameter: {}

is SN or name of access-list, value range of

acl_name

is from 1 to 99.

Default:

Default no filter condition

Command Mode:

Interface Configuration Mode

Usage Guide:

Configure interface to filter groups, permit or deny some group joining.

Example:

Configure interface vlan1 to permit group 224.1.1.1, deny group 224.1.1.2.

Switch (Config)#access-list 1 permit 224.1.1.1 0.0.0.0

Switch (Config)#access-list 1 deny 224.1.1.2 0.0.0.0

Switch (Config)#interface vlan 1

Switch(Config-If-Vlan1)#ip igmp access-group 1

16.6.3.2 ip igmp immediate-leave

Command: ip igmp immediate-leave group-list {|}

no ip igmp immediate-leave

Function:

Configure IGMP working in immediate-leave mode, that is, when the host

transmits member identity report of equivalent to leave a group, router does not transmit

query, it directly confirms there is no member of this group in subnet; the “no ip igmp

immediate-leave

” command cancels immediate-leave mode.

Parameter:

is access-list SN, value is from 1 to 99.

is access-list name.

Default:

Interface default and no immediate-leave group of configuration after finished

product

Command Mode:

Interface Configuration Mode

Usage Guide:

The command only can apply in only one host condition in subnet.

Example:

Configure immediate-leave mode on access-group list 1

Switch (Config-if-Vlan1)#ip igmp immediate-leave group-list 1

Switch (Config-if-Vlan1)#

16.6.3.3 ip igmp last-member-query-interval

Command: ip igmp last-member-query-interval

no ip igmp last-member-query-interval

Function:

Configure interval of specified group query transmitting on interface; the “no ip

igmp last-member-query-interval

” command cancels the value of user manual

configuration, and restores default value.

Parameter:

is interval of specified group query, range from 1000ms to

25000ms; the value is integer times of 1000ms, namely if input value is not integer times

of 1000ms, the system automatically changes to integer times of 1000ms.

This manual is related to the following products: