Accton Technology ES4626 User Manual
Page 159
159
the machine state and port state of the port are as follows:
mux_state: DETCH rcvm_state: P_DIS prm_state: NO_PER
actor_oper_port_state : L_A___F_
partner_oper_port_state: _TA___F_
Displayed information
Explanation
portnumber Port
number
actor_port_agg_id
The channel number to add the port to. If the port cannot be added to
the channel due to inconsistent parameters between the port and the
channel, 3 will be displayed.
partner_oper_sys System
ID of the other end.
partner_oper_key
Operational key of the other end.
actor_oper_port_key
Local end operational key
mode of the port
The mode in which port is added to the group
mac_type
Port type: standard Ethernet port and fiber-optical distributed data
interface
speed_type
Port speed type: 10Mbps, 100Mbps, 1,000Mbps and 10Gbps.
duplex_type
Port duplex mode: full-duplex and half-duplex
port_type
Port VLAN property: access port or trunk port
mux_state
Status of port binding status machine
rcvm_state
Status of port receiving status machine
prm_state
Status of port sending status machine
3. Display load balance information for port-group 1.
Switch#
show port-group 1 load-balance
The loadbalance of the group 1 based on src MAC address.
4. Display member port information for port-group 1.
Switch#
show port-group 1 port
Sorted by the ports in the group 1 :
--------------------------------------------
the portnum is 1
Ethernet port 1/1 related information:
Actor part Administrative Operational
port number 1
port priority 0x8000
aggregator id 0
port key 0x0100 0x0101