beautypg.com

2 format and severity of the log information – Accton Technology ES4626 User Manual

Page 63

background image

63

view. The other two channels---the log buffer zone and log host channel are two

important channels

SDRAM (Synchronous Dynamic Random Access Memory) and NVRAM (Non

Vulnerable Random Access Memory) is provided inside the switch as two part of the log

buffer zone, The two buffer zone record the log information in a circuit working pattern,

namely when log information need to be recorded exceeds the buffer size, the oldest log

information will be erased and replaced by the new log information, information saved in

NVRAM will stay permanently while those in SDRAM will lost when the system restarts or

encounter an power failure. Information in the log buffer zone is critical for monitoring the

system operation and detecting abnormal states.

Note: the NVRAM log buffer may not exist on some switches, which only

have the SDRAM log buffer zone

It is recommended to use the system log server. By configuring the log host

on the switch, the log can be sent to the log server for future examination

2.2.9.1.2 Format And Severity Of The Log Information

The log information format is compatible with the BSD syslog protocol, so we can

record and analyze the log by the systlog (system log protect session) on the

UNIX/LINUX, as well as syslog similar applications on PC.

The log information is classified into eight classes by severity or emergency

procedure. One level per value and the higher the emergency level the log information

has, the smaller its value will be. For example, the level of critical is 2, and warning is 4,

debugging is leveled at 7, so the critical is higher than warnings which no doubt is high

than debugging. The rule applied in filtering the log information by severity level is that:

only the log information with level equal to or higher than the threshold will be outputted.

So when the severity threshold is set to debugging, all information will be outputted and if

set to critical, only critical, alerts and emergencies will be outputted.

Follow table summarized the log information severity level and brief description.

Note: these severity levels are in accordance with the standard UNIX/LINUX syslog

Severity Value

Description

emergencies 0

System is unusable

alerts 1

Action must be taken immediately

critical 2

Critical conditions

errors 3

Error conditions

warnings 4

Warning conditions

notifications 5

Normal but significant condition

This manual is related to the following products: