Table "telecom clocking interrupt status, Is als, Table "telecom clocking – Artesyn ATCA-8310 Installation and Use (May 2014) User Manual
Page 338: Cpld and fpga

CPLD and FPGA
ATCA-8310 Installation and Use (6806800M72E)
338
IPMC Interrupt Register
Telecom Clocking Interrupt Registers
Table 8-146 IPMC KCS Interrupt Enable Register
Address: 0x9E - 0x9F
Bit Interrupt
Name
Description
Default
Access
0
KCS_IRQ
KCS Interrupt enable:
0: Disabled
1:Enabled
0
SPP: r/w
15:1
-
Reserved
0
r
Table 8-147 Telecom Clocking Interrupt Status Register
Address: 0xA0 - 0xA1
Bit Interrupt
Name
Description
Default
Access
0
ACS8520_IRQ
Interrupt from device ACS8520
0
SPP: r
1
CLK_MONITOR_FINISHE
D
Interrupt from Telecom Clock
supervision. At least one
measurement for the supervised
clocks has finished.
See Table 89 Telecom Clock Monitor
Status Register
0
SPP: r
2
CLK_MONITOR_OUT_OF
_RANGE
Interrupt from Telecom Clock
supervision. At least one supervised
clock is out of range.
See Table 90 Telecom Clock Monitor
Out of Range Register.
0
SPP: r
15:2
-
Reserved
0
r