The SPP will provide 3 MAC addresses in its FRU information:

3 x SPP to switch

1 x Terminal Server

The GPP will provide 2 MAC addresses in its FRU information:

2 x GPP to switch

1 x GPP to front

The DMC modules (onboard DSPs are treated as DMC module #0) will provide 60 MAC
addresses in its FRU information.

7.9

Reset Domains and FRU Activation/Deactivation

The ATCA-8310 provides the following FRU instances:

FRU #0: front board management and switch

FRU #1: DMC module #0

FRU #2: DMC module #1

FRU #3: DMC module #2

FRU #4: Intel CPU

FRU #5: RTM

Each FRU instance can be reset separately. Each FRU instance is implemented as a managed
FRU with having its own hot-swap state machine and FRU information.

Due to the fact that the power domains of each FRU are not separated (one power domain), the
FRUs are logically interconnected and activated/deactivated together always. It is not possible
to just activate/deactivate one single FRU.

FRU activation policy: FRU instances and RTM cannot been activated in case of the main FRU
#0 is inactive. Activating FRU #0 will activate the FRU instances as well.

FRU deactivation policy: Deactivating one FRU instance will deactivate the other FRU instances
and the main FRU. However the RTM (separate power domain) can be deactivated alone.

This manual is related to the following products: