Table 5-15, Platform thermal configuration field description, Bios – Artesyn ATCA-8310 Installation and Use (May 2014) User Manual
Page 126

BIOS
ATCA-8310 Installation and Use (6806800M72E)
126
Table 5-15 Platform Thermal Configuration Field Description
Field
Description
Critical Trip Point
This value controls the temperature of the ACPI Critical Trip Point -
the point in which the OS will shut the system off. NOTE: 100C is
the Plan Of Record (POR) for all Intel mobile processors.
Active Trip Point Lo( Fan Speed) This value controls the temperature of the ACPI Active Trip Point -
the point in which the OS will turn the processor fan on low.
Active Trip Point Hi( Fan Speed) This value controls the temperature of the ACPI Active Trip Point -
the point in which the OS will turn the processor fan on high.
Passive Trip Point
This value controls the temperature of the ACPI Passive Trip Point -
the point in which the OS will begin throttling the processor.
Passive TC1 Value
This value sets the TC1 value for the ACPI Passive Cooling Formula.
Range 1 - 16
Passive TC2 Value
This value sets the TC2 value for the ACPI Passive Cooling Formula.
Range 1 - 16
Passive TSP Value
This item sets the TSP value for the ACPI Passive Cooling Formula. It
represents in tenths of a second how often the OS will read the
temperature when passive cooling is enabled. Range 2 - 32
ME SMBus Thermal Repo(rting) Enable/Disable ME SMBus Thermal Reporting Configuration
SMBus Buffer Length
SMBus Block Read message length for EC.
Thermal Reporting E(C PEC)
Enable Packet Error Checking (PEC) for SMBus Block Read
Select slots with TS on
DIMM's
Enable temperature reporting for slots with TS on DIMM. NOTE:
SODIMM0 is the one closer to CPU.
MCH Temp Read
MCH Temperature Read Enable
PCH Temp Read
PCH Temperature Read Enable
CPU Energy Read
CPU Energy Read Enable
CPU Temp Read
CPU Temperature Read Enable
Alert Enable Lock
Lock all Alert Enable settings