Intelligent Peripheral Management Controller
ATCA-8310 Installation and Use (6806800M72E)
235
The IPMI command "Set System Boot Options" together with the parameter #96 can be used to
specify the payload boot-bank from which the payload shall boot from persistently.
The Intel CPU can select its boot bank by selecting the boot bank register in the Glue Logic
FPGA. The SPP is evaluating the boot bank register to manage the boot bank selection.
7.17 Settable Graceful Shutdown Timeout
The IPMI command "Set System Boot Options" together with the parameter #98 can be used to
specify the timeout for Graceful Shutdown persistently. The value of the graceful shutdown
timeout is specified for both CPU's.
By default, this value is set to 10 seconds.
Figure 7-6
Payload Boot Bank Selection
Boot Flash B
Boot flash A
SP
I
Intel
Boot Flash B
Boot flash A
SP
I
P4080
Renesas H8S
2166 (IPMC)
Glue Logic FPGA
CS #0
CS #1