background image

U-Boot

ATCA-8310 Installation and Use (6806800M72E)

178

The parameters to the "fru" command are

open
To open a local FRU, where is

0 for the SPP FRU

1 for the FRU of the onboard DSP module (DMC0)

2 for the 1st DMC module

3 for the 2nd DMC module

4 for the GPP FRU

5 for the RTM baseboard

6 for the RTM mezzanine card

close
Closes the currently opened fru data

save
Saves modifications to the fru data

set
Set various parameters in the currently opened fru data

show
Display the currently opened fru data

FRU information on the shelf manager can be viewed using the "ipmi fru remote shm"
command. For example, to display the shelf FRU information provided by the shelf manager,
call:

ipmi fru remote shm 254

fru show

fru close

It is not recommended for the customer to modify FRU data. This feature is intended for
factory use only.