6.2.1.4.2 Environment Variables Passed to the GPP

The SPP passes information to the GPP in the first 512 bytes of the FPGA shared memory area.

The format of this shared memory area is:

Bytes 0/1 form the length code (Byte 0 is the lsb, byte 1 the msb)

Bytes 2 .. +1 contains the parameter information. Parameters are passed as zero-
terminated = ASCII strings. The last parameter string is terminated with
two zero bytes.

Bytes + 2 (lsb) and +3 (msb) contains the checksum over the parameter
information.

U-Boot initializes the parameter area with the following name/value pairs before releasing the
GPP from reset):

3

BIOS EnterSetup

The BIOS setup menu has been entered.

4

BIOS PrepareToBoot

XXX

15

BIOS Boot

XXX

29

BIOS end

XXX

>= 30

User defined OS run levels

Can be used by the Operating system to report further
progress messages.

Table 6-4 GPP Run Levels (continued)

Value

Mnemonic

Description

Table 6-5 U-Boot Name/Value Pairs

Name

Value (Corresponding U-Boot Variable)

Description

btime

$v_boottime

Boot time of blade

slot_p

$v_physical_slot

Physical slot of blade

slot_l

$v_logical_slot

Logical slot of blade

shelf

$v_shelf_id

Shelf identifier

sname

$v_shelf_name

The name of the shelf stored in the shelf FRU
information (product area).

spnum

$v_shelf_prid

The product ID of the shelf