Table 8-40, Logical device configuration register summary, Table 8-41 – Artesyn ATCA-8310 Installation and Use (May 2014) User Manual
Page 272: Logical device enable register, Cpld and fpga

CPLD and FPGA
ATCA-8310 Installation and Use (6806800M72E)
272
Logical Device Configuration Registers
Use to access the registers that are assigned to each logical unit. The Super IO supports two
logical units and has two sets of logical device registers. The two logical devices are COM 1
(Logical Number 4) and COM 2 (Logical Number 5). A separate set (bank) of control and
configuration registers exists for each logical device and is selected with the Logical Device
Number Register. The INDEX PORT is used to select a specific logical device register. These
registers are then accessed through the DATA PORT. The Logical Device registers are accessible
only when the device is in the Configuration state.
The logical register addresses are shown in the tables below.
Table 8-40 Logical Device Configuration Register Summary
Index Address
Description
0x30
Enable
0x60
Base IO Address MSB
0x61
Base IO Address LSB
0x70
Primary Interrupt Select
0x74
Reserved
0x75
Reserved
0xF0
Reserved
Table 8-41 Logical Device Enable Register
Index Address: 0x30
Bit
Description
Default
Access
0
Logical Device Enable:
0: disabled. Currently selected device is inactive.
1: enabled. . The currently selected device is enabled.
1
GPP: r/w
7:1
Reserved
0
r