beautypg.com

Table 8-40, Logical device configuration register summary, Table 8-41 – Artesyn ATCA-8310 Installation and Use (May 2014) User Manual

Page 272: Logical device enable register, Cpld and fpga

background image

CPLD and FPGA

ATCA-8310 Installation and Use (6806800M72E)

272

Logical Device Configuration Registers

Use to access the registers that are assigned to each logical unit. The Super IO supports two
logical units and has two sets of logical device registers. The two logical devices are COM 1
(Logical Number 4) and COM 2 (Logical Number 5). A separate set (bank) of control and
configuration registers exists for each logical device and is selected with the Logical Device
Number Register. The INDEX PORT is used to select a specific logical device register. These
registers are then accessed through the DATA PORT. The Logical Device registers are accessible
only when the device is in the Configuration state.

The logical register addresses are shown in the tables below.

Table 8-40 Logical Device Configuration Register Summary

Index Address

Description

0x30

Enable

0x60

Base IO Address MSB

0x61

Base IO Address LSB

0x70

Primary Interrupt Select

0x74

Reserved

0x75

Reserved

0xF0

Reserved

Table 8-41 Logical Device Enable Register

Index Address: 0x30

Bit

Description

Default

Access

0

Logical Device Enable:
0: disabled. Currently selected device is inactive.
1: enabled. . The currently selected device is enabled.

1

GPP: r/w

7:1

Reserved

0

r

This manual is related to the following products: