Intelligent Peripheral Management Controller

ATCA-8310 Installation and Use (6806800M72E)

232

Ipmicmd -k "0 0 2e 15 cd 65 0 3 0 0" smi 0

9. Open the telnet session

telnet

To configure channel 6 of the terminal server please execute command 1-7 again but replace
the channel argument from 5 to 6 and do not use the same IP address. Two telnet sessions are
possible at the same time.

To redirect the serial line of the SPP from front connector to the TS, please execute the
following command:

Ipmicmd -k "0 0 2e 15 cd 65 0 3 1 1" smi 0

7.14 Fail Safe Logic and Watchdog Support

The IPMC firmware supports automatic fail safe logic for the payload firmware on the SPP.

7.14.1 SPP BMC Watchdog

When the IPMC transitions to M4 (Active), the IPMC automatically enables the BMC Watchdog
with the following settings:

Timer Use: BIOS/POST

Timer Actions: Hard Reset

Timer Countdown Value: 30 Seconds

SPP firmware (U-Boot) must disable or reset the BMC Watchdog within 30 seconds of payload
activation. Failure to disable or reset the BMC Watchdog will result in the IPMC performing a
payload reset.