5 send sw progress data, Table 7-16, Send sw progress data command – Artesyn ATCA-8310 Installation and Use (May 2014) User Manual
Page 243: Intelligent peripheral management controller

Intelligent Peripheral Management Controller
ATCA-8310 Installation and Use (6806800M72E)
243
7.22.5 Send SW Progress Data
This command can be used to feed the SW Progress Sensors.
Table 7-16 Send SW Progress Data Command
Byte
Data Field
Request Data
1
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be used.
2
2nd byte of Artesyn IANA Enterprise Number. A value of 65h shall be used.
3
MSB of Artesyn IANA Enterprise Number. A value of 00h shall be used.
4
Sensor Type
DD = SW Progress 1
DE = SW Progress 2
DF = SW Progress 3
5
Event Data Byte 1
6
Event Data Byte 2
7
Event Data Byte 3
Response Data
1
Completion Code.
2
LSB of Artesyn IANA Enterprise Number. A value of CDh shall be used.
3
2nd byte of Artesyn IANA Enterprise Number. A value of 65h shall be used.
4
MSB of Artesyn IANA Enterprise Number. A value of 00h shall be used.