5.4.2
SEC Progress
5.4.3
SEC Errors
0xF0 - 0xF8
Recovery progress (PEI)
0xF9 - 0xFF
Recovery errors (PEI)
Table 5-39 Status Code Ranges (continued)
Status Code Range
Description
Table 5-40 SEC Progress
Status Code
Description
0x01
Power on. Reset type detection (soft/hard).
0x02
AP initialization before microcode loading
0x03
NB initialization before microcode loading
0x04
SB initialization before microcode loading
0x05
OEM initialization before microcode loading
0x06
Microcode loading
0x07
AP initialization after microcode loading
0x08
NB initialization after microcode loading
0x09
SB initialization after microcode loading
0x0A
OEM initialization after microcode loading
0x0B
Cache initialization
Table 5-41 SEC Errors
Error Code
Description
0x0C - 0x0D
Reserved for future AMI SEC error codes