beautypg.com

1 mac address fru oem records, Table 7-4, Aryesyn ecc mac address record – Artesyn ATCA-8310 Installation and Use (May 2014) User Manual

Page 222: Intelligent peripheral management controller

background image

Intelligent Peripheral Management Controller

ATCA-8310 Installation and Use (6806800M72E)

222

7.8.1

MAC Address FRU OEM Records

The Artesyn Embedded Technologies MAC Address record is specified in the following:

0xA6

IPMC

Front blade

SEL

0xA0

IPMC

Base Switch

Config EEPROM

Device internal

MMC

RTM

FRU Information

MMC

RTM Mezzanine Module

FRU Information

Table 7-3 FRU information EEPROM Storage (continued)

I2C Address

I2C bus

Domain

Purpose

Table 7-4 Artesyn ECC MAC Address Record

Offset

Length

Description

0

1

Record Type ID. A value of C0h (OEM) shall be used for Artesyn ECC
OEM records.

1

1

End of List/Version
[7] End of List. Set to 1b for the last record.
[6:4] Reserved. Write as 000b.
[3:0] Record format version. Write as 2h.

2

1

Record Length

3

1

Record Checksum (zero checksum)

4

1

Header Checksum (zero checksum)

5

1

LSB of Manufacturer ID. Write as CDh.

6

1

Second Byte of Manufacturer ID. Write as 65h.

7

1

MSB of Manufacturer ID. Write as 00h.

8

1

Motorola Record ID. 01h for Artesyn ECC MAC Address Record.

9

1

Record Format Version. 01h for this specification.

10

1

Number of MAC Address Descriptors (N).

11

N*9

Artesyn ECC MAC Address Descriptors. Refer to Table 5, Artesyn ECC
MAC Address Descriptor