CPLD and FPGA

ATCA-8310 Installation and Use (6806800M72E)

260

8.1.5.3.4 Configuration CRC Error

During normal operation the operation the Configuration is periodically checked by dedicated
FPGA internal logic. In the case of a CRC error the signal CONF_CRC_ERR is asserted to signal
the system, that FPGA logic may be corrupted.

Such an error is handled like a power failure.

8.1.5.4

CPLD Serial Redirection

Figure 8-2

CPLD Serial Redirection

IPMC_TXD

IPMC_RXD

IPMC_COM2FP

CPLD

IMPC

Debug

FPGA

COM1

3

PinHeader

Face

Plate

COM1

FPGA_COM1_TXD

FPGA_COM1_RXD

IPMC_RXD_CON

FP_COM1_TXD

FP_COM1_RXD

IPMC_COM2FP

=0

or

SWITCH[4]on:

IPMC_COM2FP

=1

or

SWITCH[1]on: