beautypg.com

8 garp timer leave, 9 garp timer leaveall, 8 garp timer leave -32 – PLANET WGSW-52040 User Manual

Page 263: 9 garp timer leaveall -32

background image

17-32

17.1.8 garp timer leave

Command:

garp timer leave <500-1200>

Function:

Set the value of garp leave timer, note that the value of leave timer must be double of join timer and less than

leaveAll timer.

Parameters:

<500-1200>, the value of timer in millisecond

Command Mode:

Global mode

Default:

600 ms.

Usage Guide:

Check whether the value satisfy the range. If so, modify the value of garp timer to the specified value, otherwise

return a configuration error.

Example:

Set the value of garp leave timer as 600ms.

Switch(config)#garp timer leave 600

17.1.9 garp timer leaveAll

Command:

garp timer leaveall <5000-60000>

Function:

Set the value of garp leaveAll timer, note that the value of leaveAll timer must be larger than leave timer.

Parameters:

<5000-60000>, the value of timer in millisecond