Usage Guide:

Use this command to configure the transmission interval of Information OAMPDU which keep OAM connection

normally.

Example:

Set the transmission interval of Information OAMPDU for ethernet 1/4 to be 2s.

Switch(Config-If-Ethernet1/4)# ethernet-oam period 2

11.22 ethernet-oam remote-failure

Command:

ethernet-oam remote-failure

no ethernet-oam remote-failure

Function:

Enable remote failure indication of OAM, no command disables the function.

Parameters:

None.

Command Mode:

Port mode

Default:

Enable.

Usage Guide:

With remote failure indication is enabled, if critical-event or link fault event is occurred locally, it will notify the peer by

sending Information OAMPDU, log the fault information and send SNMP trap warning. When the remote failure

indication is disabled, although local critical-event or link fault event is not monitored, failure indication information

from the peer is still normally received and processed.

Example:

Enable remote failure indication of ethernet 1/4.

Switch(Config-If-Ethernet1/4)#ethernet-oam remote-failure