18 ethernet-oam errored-symbol-period window, Ethernet, Oam errored – PLANET WGSW-52040 User Manual
Page 212: Symbol, Period window

11-211
Default:
1.
Usage Guide:
During the specific detection period, errored symbol event is induced if the number of errored symbols is larger than
or equal to the low threshold and the device notifies the peer by sending event notification OAMPDU. Note that the
low threshold should not be larger than the high threshold.
Example:
Set the low threshold of errored symbol event on port 1/4 to be 5.
Switch(Config-If-Ethernet1/4)#ethernet-oam errored-symbol-period threshold low 5
11.18 ethernet-oam errored-symbol-period window
Command:
ethernet-oam errored-symbol-period window <seconds>
no ethernet-oam errored-symbol-period window
Function:
Configure the detection period of errored symbol event, no command restores the default value.
Parameters:
<seconds> is the time for counting the specified frame number, its range from 5 to 300, unit is 200ms.
Command Mode:
Port mode
Default:
5.
Usage Guide:
Detect errored symbols of the port after the time of specific detection period. If the number of errored symbols is
larger than or equal to the threshold, corresponding event is induced and the device notified the peer through
OAMPDU.
Example:
Set the detection period of errored symbol event on port 1/4 to be 2s.