13-6

Set the threshold defined by the user.

Parameters:

default: Restore the threshold as the default threshold set by the manufacturer. If the monitoring index is not

specified, restore all thresholds, if the monitoring index is specified, restore the corresponding threshold only.

temperature:The monitoring index—temperature

voltage:The monitoring index—voltage

bias:The monitoring index—bias current

rx-power:The monitoring index—receiving power

tx-power:The monitoring index—sending power

high-alarm:High-alarm of the monitoring index, namely there is alarm with A+ if exceeding the threshold.

low-alarm:Low-alarm of the monitoring index, namely there is alarm with A- if exceeding the threshold.

high-warn:High-warn of the monitoring index, namely there is warning with W+ if exceeding the threshold.

low-warn:Low-warn of the monitoring index, namely there is warning with W- if exceeding the threshold.

Command Mode:

Port mode

Default:

The threshold is set by the manufacturer.

Usage Guide:

The range of the threshold parameters is shown for each monitoring index in the following:

Temperature: -128.00~128.00 ℃

Voltage: 0.00~7.00 V

Bias current: 0.00~140.00 mA

x-power: -50.00~9.00 dBM

tx-power: -50.00~9.00 dBM

The maximum length of the threshold parameter configured by the user is 20 bits. After the user configured a

parameter threshold, the threshold set by the manufacturer will be labeled with the bracket when showing the

threshold, and decide whether give an alarm according to the user’s configuration.

Example:

Configure tx-power threshold of the fiber module, the low-warn threshold is configured as -12 on ethernet1/1.

Switch(config-if-ethernet1/1)#transceiver threshold tx-power low-warning -12