7.6 Avantes Spectrometer
■■■■■■■■■■■■■■■■■■■■■■
886
■■■■■■■■
viva 1.1 (for process analysis)
7.6.6
Properties - Dark spectrum
Tab: Configuration
▶ Devices ▶ [Edit] ▶ Properties... ▶ Properties - 'Device type' -
'Device name'
▶ Dark spectrum
The Dark spectrum tab shows information on the dark spectrum stored
in the device.
If no dark spectrum has been recorded yet or the calibration has been
reset to factory settings, -- is displayed in the fields.
Date
Shows the date and time when the dark spectrum was recorded.
User
Shows the user logged in during recording of the dark spectrum.
Method
Shows the method with which the dark spectrum has been recorded.
Determination ID
ID of the determination in which the dark spectrum has been recorded.
The determination ID can be copied and pasted into another field.
Integration time
Shows the integration time during recording of the dark spectrum.
Averaged spectra
Number of spectra recorded and averaged.
Smoothing
Shows the number of neighboring pixels with which the light intensity of
each pixel was determined.
Spectrum
Shows the dark spectrum. The graph can be zoomed with the mouse. The
whole spectrum is displayed again by double-clicking on the graph.
x axis
Shows the wavelength in nm.
y axis
Shows the intensity in Counts.