10.4.6.3 Column Address to First Data OutÑCAS Latency
This parameter, controlled by P/LSDMR[CL], deÞnes the timing for Þrst read data after a
column address is sampled by the SDRAM.
Figure 10-22. CL = 2 (2 Clock Cycles)
10.4.6.4 Last Data Out to Precharge
This parameter, controlled by P/LSDMR[LDOTOPRE], deÞnes the earliest timing for the
PRECHARGE
command after the last data was read from the SDRAM. It is always related to
the CL parameter.
Figure 10-23. LDOTOPRE = 2 (-2 Clock Cycles)
CLK
ALE
CSn
SDRAS
SDCAS
MA[0Ð11]
Row
Column
WE
DQMn
Data
D0
D1
D2
D3
Activate
Read
First data out
CL = 2
CLK
ALE
CS
SDRAS
SDCAS
MA[0Ð11]
Row
Column
WE
Data
D0
D1
D2
D3
Activate
Read
Deactivate
Last Data Out
LDOTOPRE = 2
DQM