Bus configuration register (bcr) -26, Bcr field descriptions -26, Table 4-9 describes bcr þelds – Motorola MPC8260 User Manual
Page 164
4-26
MPC8260 PowerQUICC II UserÕs Manual
MOTOROLA
Part II. ConÞguration and Reset
Table 4-9 describes BCR Þelds.
Bits
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Field
EBM
APD
L2C
L2D
PLDP EAV
Ñ
ETM LETM EPAR LEPAR
Reset
Depends on reset conÞguration sequence. See Section 5.4.1, ÒHard Reset ConÞguration Word.Ó
R/W
R/W
Bits
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Field
NPQM
Ñ
EXDD
Ñ
ISPS
Ñ
Reset
Depends on reset conÞguration sequence. See Section 5.4.1, ÒHard Reset ConÞguration Word.Ó
R/W
R/W
Addr
Figure 4-21. Bus Configuration Register (BCR)
Table 4-9. BCR Field Descriptions
Bits
Name
Description
0
EBM
External bus mode.
0 Single MPC8260 bus mode is assumed
1 60x-compatible bus mode. For more information refer to Section 8.2, ÒBus ConÞguration.У
1Р3
APD
Address phase delay. SpeciÞes the minimum number of address tenure wait states for address
operations initiated by a 60x bus master. BCR[APD] speciÞes the minimum number of address
tenure wait states for address operations initiated by 60x-bus devices. APD indicates how many
cycles the MPC8260 should wait for ARTRY, but because it is assumed that ARTRY can be
asserted (by other masters) only on cachable address spaces, APD is considered only on
transactions that hit one of the 60x-assigned memory controller banks and have the GBL signal
asserted during address phase.
4
L2C
Secondary cache controller. See Chapter 11, ÒSecondary (L2) Cache Support.Ó
0 No secondary cache controller is assumed.
1 An external secondary cache controller is assumed.
5Ð7
L2D
L2 cache hit delay. Controls the number of clock cycles from the assertion of TS until HIT is valid.
8
PLDP
Pipeline maximum depth. See Section 8.4.5, ÒPipeline Control.Ó
1 The pipeline maximum depth is zero.
0 The pipeline maximum depth is one.
9
EAV
Enable address visibility. Normally, when the MPC8260 is in single-MPC8260 bus mode, the bank
select signalsfor SDRAM accesses are multiplexed on the 60x bus address lines. So, for SDRAM
accesses, the internal address is not visible for debug purposes. However the bank select signals
can also be driven on dedicated pins (see SIUMCR[APPC]). In this case EAV can be used to force
address visibility.
0 Bank select signals are driven on 60x bus address lines. There is no full address visibility.
1 Bank select signals are not driven on address bus. During READ and WRITE commands to
SDRAM devices, the full address is driven on 60x bus address lines.
10Р11
С
Reserved, should be cleared.
12
ETM
Compatibility mode enable. See Section 8.4.3.8, ÒExtended Transfer Mode.Ó
0 Strict 60x bus mode. Extended transfer mode is disabled.
1 Extended transfer mode is enabled.