beautypg.com

Basler Electric DGC-2020 User Manual

Page 80

background image

ECU Parameter

Metric

Units

English

Units

Update Rate

SPN

DEF Tank 2 Level

%

%

1 s

4367

ECU Temperature

°C

°F

1 s

1136

Engine Coolant Preheated State

Binary (0 or 1)

500 ms

3552

Engine Coolant Temperature

°C

°F

1 s

110

Engine Desired Operating Speed

rpm

rpm

250 ms

515

Engine Intake Manifold #1 Absolute Pressure

kPa

psi

500 ms

3563

Engine Intercooler Coolant Level

%

%

500 ms

3668

Engine Intercooler Temperature

°C

°F

1 s

52

Engine Oil Level

%

%

500 ms

98

Engine Oil Pressure

kPa

psi

500 ms

100

Engine Oil Temperature

°C

°F

1 s

175

Engine Speed

rpm

rpm

Engine Speed

Dependent

190

Exhaust Gas Temperature

°C

°F

500 ms

173

Exhaust Temperature A

°C

°F

500 ms

2433

Exhaust Temperature B

°C

°F

500 ms

2434

Fuel Delivery Pressure

kPa

psi

500 ms

94

Fuel Leak Filter 1

Binary (0 or 1)

1 s

1239

Fuel Leak Filter 2

Binary (0 or 1)

1 s

1240

Fuel Rate

liter/hr

gal/hr

100 ms

183

Fuel Temperature

°C

°F

1 s

174

High Exhaust System Temp (HEST) Lamp/Indicator

500 ms

3698

Injection Control Pressure

MPa

psi

500 ms

164

Injector Metering Rail Pressure

MPa

psi

500 ms

157

Intake Manifold Temperature

°C

°F

500 ms

105

Particulate Filter (DPF) Lamp/Indicator

500 ms

3697

Percent Load at Current rpm

%

%

50 ms

92

Rated Power

watts

watts

On Request

166

Rated rpm

rpm

rpm

On Request

189

Regeneration Disabled (Inhibit) Lamp/Indicator

500 ms

3703

Shutdown from ECU

Binary (0 or 1)

1 s

1110

Switched Battery Voltage (at ECU)

Vdc

Vdc

1 s

158

Throttle (Accelerator Pedal) Position

%

%

50 ms

91

Total Engine Hours

hours

hours

Requested 1.5 s

247

Total Fuel Used

liters

gallons

Requested 1.5 s

250

Transmission Oil Pressure

kPa

psi

1 s

127

Transmission Oil Temperature

°C

°F

1 s

177

Trip Average Fuel Rate

liters

gallons

500 ms

1029

Trip Fuel

liters

gallons

Requested 1.5 s

182

Winding 1 Temperature

°C

°F

1 s

1124

Winding 2 Temperature

°C

°F

1 s

1125

Winding 3 Temperature

°C

°F

1 s

1126

∗ SPN is suspect parameter number.