Register

Description

Type

Units

Scaling

Factor

R/W

Range

46540

AEM Input 6 Max
Current

Int32

Milliamp x 10

Deci

RW

40 - 200

46542

AEM Input 6 Min
Voltage

Int32

DeciVolt

Deci

RW

0 - 100

46544

AEM Input 6 Min
Current

Int32

Milliamp x 10

Deci

RW

40 - 200

46546

AEM Input 6 Param Max

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46548

AEM Input 6 Param Min

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46550

AEM Input 6 Hysteresis

Int32

Deci Percent

Deci

RW

0 – 1000

46552

AEM Input 6 Arming
Delay

Int32

Second

N/A

RW

0 – 300

46554

AEM Input 6 Threshold
1 Activation Delay

Int32

Second

N/A

RW

0 – 300

46556

AEM Input 6 Threshold
2 Activation Delay

Int32

Second

N/A

RW

0 – 300

46558

AEM Input 6 Over 1
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46560

AEM Input 6Over 2
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46562

AEM Input 6 Under 1
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46564

AEM Input 6Under 2
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46566

AEM Input 6 Over 1
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46568

AEM Input 6 Over 2
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46570

AEM Input 6 Under 1
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46572

AEM Input 6 Under 2
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46574

AEM Input 6 Out of
Range Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46576

AEM Input 7 Max
Voltage

Int32

DeciVolt

Deci

RW

0 - 100

46578

AEM Input 7 Max
Current

Int32

Milliamp x 10

Deci

RW

40 - 200

46580

AEM Input 7 Min
Voltage

Int32

DeciVolt

Deci

RW

0 - 100

46582

AEM Input 7 Min
Current

Int32

Milliamp x 10

Deci

RW

40 - 200

46584

AEM Input 7 Param Max

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46586

AEM Input 7 Param Min

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46588

AEM Input 7 Hysteresis

Int32

Deci Percent

Deci

RW

0 – 1000

46590

AEM Input 7 Arming
Delay

Int32

Second

N/A

RW

0 – 300

46592

AEM Input 7 Threshold
1 Activation Delay

Int32

Second

N/A

RW

0 – 300

46594

AEM Input 7 Threshold
2 Activation Delay

Int32

Second

N/A

RW

0 – 300

46596

AEM Input 7 Over 1
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46598

AEM Input 7Over 2
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900