BESTCOMSPlus®

Version and Date

Change

2.05.00, 07/09

Made a correction to announce a message that logic will not be saved
if the maximum number of logic gates on any one level has been
exceeded.

On the Breaker Management, Breaker Hardware screen, changed the
Gen and Mains Breaker Closing Time from 0.1-600 in increments of
0.1 to 0-800 in increments of 5.

Corrected Settings Compare error when there are remote outputs or
logic control relay outputs in the logic diagram.

2.04.01, 05/09

Changes invisible to the user.

2.03.01, 02/09

Added “P” (programmable) curve selection for the 51 function.

Improvement to allow spaces in Initializing Message 1 & 2 on General
Settings, Front Panel HMI
screen in the Settings Explorer.

Improved backwards compatibility.

Improved Commission Date setting on Run Statistics screen in the
Metering Explorer.

2.03.00, 12/08

Added support for CEM-2020H.

Added Export to File feature.

Added settings for Phase Toggle and Initializing Messages on General
Settings, Front Panel HMI
screen.

Re-arranged CANbus Setup screen and added ECU Setup screen
under Communications.

Added settings for 51-3 element under Generator Protection, Current.

Added setting for Off Mode Cooldown on System Parameters, System
Settings
screen.

Added Remote Module Setup screen under System Parameters.

Added Remote LSM Inputs settings and metering screens under
Programmable Inputs.

Added settings to Bias Control screens for Var/PF control.

Added kvar A, B, C, and Total to Power and Summary metering
screens.

Re-arranged MTU metering screens.

Added MTU Status screen and MTU Engine Status screen.

Added BESTlogicPlus Input Objects for Configurable Elements,
Configurable Protection, Front Panel Buttons, PF Mode Active, Pre
Start Input, and Run Input.

Added BESTlogicPlus Pre-Alarms for Checksum Fail and CEM
Hardware Mismatch.

Added BESTlogicPlus Elements for 51-3, COOLSTOPREQ,
COOLDOWNREQ, EXTSTARTDEL, PRESTARTOUT, RUNOUTPUT,
STARTDELBYP, and STARTOUTPUT.

Added Relay Control settings on System Parameters, System Settings
screen.

2.02.01, 10/08

Maintenance release (BE1-11 changes)

2.01.00, 05/08

Added settings for AEM-2020.

Added settings for Automatic Generator Protection.

Added settings for Integrating Reset on 51 function.

Added settings for Configurable Protection.

2.00.01, 03/08

Added settings for CEM-2020.

1.04.01, 11/07

Added settings for LSM-2020.

viii

DGC-2020 Introduction

9400200990 Rev X