Device security setup, Device security setup -17 – Basler Electric DGC-2020 User Manual
Page 127
![background image](https://www.manualsdir.com/files/773941/content/doc127.png)
L
Application Version: Read-only value obtained when BESTCOMSPlus is communicating with an
optional LSM-2020.
M
Boot Code Version: Read-only value obtained when BESTCOMSPlus is communicating with an
optional LSM-2020.
N
Application Build Date: Read-only value obtained when BESTCOMSPlus is communicating with an
optional LSM-2020.
O
Serial Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional
LSM-2020.
P
Application Part Number: Read-only value obtained when BESTCOMSPlus is communicating with an
optional LSM-2020.
Q
Model Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional
LSM-2020.
R
Application Version: Read-only value obtained when BESTCOMSPlus is communicating with an
optional CEM-2020.
S
Boot Code Version: Read-only value obtained when BESTCOMSPlus is communicating with an
optional CEM-2020.
T
Application Build Date: Read-only value obtained when BESTCOMSPlus is communicating with an
optional CEM-2020.
U
Serial Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional
CEM-2020.
V
Application Part Number: Read-only value obtained when BESTCOMSPlus is communicating with an
optional CEM-2020.
W
Model Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional
CEM-2020.
X
Application Version: Read-only value obtained when BESTCOMSPlus is communicating with an
optional AEM-2020.
Y
Boot Code Version: Read-only value obtained when BESTCOMSPlus is communicating with an
optional AEM-2020.
Z
Application Build Date: Read-only value obtained when BESTCOMSPlus is communicating with an
optional AEM-2020.
AA
Serial Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional
AEM-2020.
BB
Application Part Number: Read-only value obtained when BESTCOMSPlus is communicating with an
optional AEM-2020.
CC
Model Number: Read-only value obtained when BESTCOMSPlus is communicating with an optional
AEM-2020.
Device Security Setup
Password protection guards against unauthorized changing of DGC-2020 settings. DGC-2020 passwords
are case sensitive. Three levels of password protection are available. Each level is described in the
following paragraphs.
•
OEM Access. This password level allows access to all settings. The default, OEM-access password
is OEM.
•
Settings Access. This password level allows all except uploading of firmware and clearing of device
event log. The default, settings-access password is SET.
•
Operator Access. The default, operator-access password is OP. This password level allows all
settings to be read and allows changes to be made to the following:
o
LCD Contrast
o
Sleep Mode
o
Date/Time
o
All Sender Fail Time Delays
o
Metric Conversion
o
Low Fuel Pre-Alarm Level
o
Low Fuel Alarm Level
o
Pre-Start Contact after Cranking
o
Cooldown Time
o
Pre-Crank Time Delay
9400200990 Rev X
DGC-2020 BESTCOMSPlus
® Software
4-17