Programmable outputs, Contact outputs, Programmable outputs -47 – Basler Electric DGC-2020 User Manual
Page 157: Contact outputs -47, Figure 4-40. remote thermocouple input #1 -47

The BESTCOMSPlus Remote Thermocouple Input #1 screen is illustrated in Figure 4-40.
Figure 4-40. Remote Thermocouple Input #1
A
Label Text: An alphanumeric character string with a maximum of 16 characters.
B
Hysteresis: Adjustable from 0 to 100% in 0.1% increments.
C
Arming Delay: Adjustable from 0 to 300 s in 1 s increments.
D
Alarm Configuration: None, Alarm, Pre-Alarm, or Status Only.
E
Threshold: Adjustable from 32 to 2,507
°F in 1°F increments or 0 to 1,375°C in 1°C increments.
F
Activation Delay: Adjustable from 0 to 300 s in 1 s increments.
Programmable Outputs
DGC-2020 programmable outputs include four user-programmable contact outputs if the style number is
xxAxxxxxx. If the style number is xxBxxxxxx, twelve contact outputs are provided. An additional 24
contact outputs are provided with an optional CEM-2020 (Contact Expansion Module). An optional CEM-
2020H (Contact Expansion Module - High Current) provides 18 contact outputs.
Contact Outputs
To make identifying the contact outputs easier, each of the contact outputs can be given a user-assigned
name with a maximum of 16 alphanumeric characters.
The contact outputs are incorporated into a BESTlogicPlus programmable logic scheme by selecting
them from the I/O group in BESTlogicPlus. For more details, refer to Section 5, BESTlogicPlus
Programmable Logic.
The BESTCOMSPlus Contact Outputs screen is illustrated in Figure 4-41.
9400200990 Rev X
DGC-2020 BESTCOMSPlus
® Software
4-47