Basler Electric DGC-2020HD User Manual
Instruction manual, For dgc-2020hd digital genset controller
Table of contents
Document Outline
- Cover
- Preface
- Contents
- Introduction
- Specifications
- Operating Power
- Battery Ride Through
- Current Sensing
- Voltage Sensing
- Analog Sensing
- Contact Sensing
- Engine System Inputs
- Output Contacts
- Metering
- Generator Protection Functions
- Logic Timers
- Communication Interface
- Real-Time Clock
- LCD Heater
- Type Tests
- Environment
- UL Approval
- CSA Certification
- NFPA Compliance
- CE Compliance
- Physical
- Mounting
- Terminals and Connectors
- Terminals
- Operating Power
- Generator Current Sensing
- Programmable Current Sensing
- Generator Voltage Sensing
- Bus Voltage Sensing
- Engine Sender Inputs
- Analog Inputs
- Magnetic Pickup Input
- Contact Sensing Inputs
- Output Contacts
- CAN Interface
- RS-485 Interface
- Automatic Voltage Regulator (AVR) Control
- Governor (GOV) Control
- Load Share Line
- IRIG-B Connections
- Optional Remote Display Panel Connections
- Connectors
- Terminals
- Typical Applications
- Controls and Indicators
- Power Input
- Voltage and Current Sensing
- Engine Sender Inputs
- Speed Signal Inputs
- Contact Inputs
- Analog Inputs
- Contact Outputs
- Operating Modes
- Breaker Management
- Synchronizer
- Bias Control
- Multiple Generator Management
- Generator Protection
- Configurable Protection
- Metering
- Reporting and Alarms
- BESTCOMSPlus®
- BESTlogic™Plus
- Communication
- Configuration
- Device Information
- Security
- Timekeeping
- Maintenance and Troubleshooting
- Maintenance
- Storage
- Troubleshooting
- Communications
- Inputs and Outputs
- Metering/Display
- Incorrect Display of Battery Voltage, Coolant Temperature, Oil Pressure, or Fuel Level
- Incorrect Display of Generator Voltage
- Incorrect Measurement or Display of Generator Current
- Incorrect Display of Engine RPM
- DGC-2020HD Indicates Incorrect Power Factor
- LCD is Blank and all LEDs are Flashing at Approximately 2 Second Intervals
- Generator Breaker and Mains Breaker
- Synchronizer
- Determining if the Synchronizer is Active
- Synchronizer Not Active
- Synchronizer Active for a Short Time, Then Stops
- Synchronizer Does Not Lower Engine Speed Allowing Alignment of Bus and Generator
- Synchronizer Does Not Raise Engine Speed Allowing Alignment of Bus and Generator
- Synchronizer Does Not Lower the Generator Voltage to Achieve Matching of Bus and Generator Voltages
- Synchronizer Does Not Raise Generator Voltage to Achieve Matching of Bus and Generator Voltages
- Speed Bias
- Voltage Bias
- Load Sharing
- DGC-2020HD Front Panel Diagnostics Screens
- AEM-2020
- CEM-2020
- Features
- Specifications
- Functional Description
- Mounting
- Connections
- CEM-2020 Configuration
- Remote Contact Inputs Configuration
- Remote Contact Outputs Configuration
- Firmware Updates
- Repair
- Maintenance
- Storage
- Time Curve Characteristics
- Tuning PID Settings
- MTU Fault Codes
- Exhaust Treatment
- Diagnostic Trouble Codes
- Revision History