Basler Electric DGC-2020 User Manual
Page 14
Firmware Package
Version and Date
Change
1.09.00, 07/09
•
Corrected transmittal of parameters to engine for MDEC module types
201, 302, and 303.
•
Implemented most recent MTU fault codes.
•
Engine Total Run Time in metering now displays hours and minutes.
Engine Total Run Time previously displayed hours only.
•
Added front panel diagnostics to show Modbus Read Count, Modbus
Write Count, and Serial Flash Write Count.
•
Modbus
legacy registers 40019 and 40020 are now read/write.
Previously these registers were write only.
•
Improved MCS5 parameter handling.
•
Fixed spurious High Charge Air Temp Pre-Alarm every time engine
starts on MTU-ECU7 machines.
•
Accelerator pedal position is now sent to Volvo ECU for load sharing.
•
Modified generator breaker logic to allow closure of generator breaker
from a dead gen to a dead bus (if Dead Bus Close Enable is selected).
In previous versions of firmware, closure of the generator breaker from
a dead generator was not possible.
1.08.01, 01/09
•
Added support for CEM-2020H.
•
Changed time dial range of 51 element fixed time curve from 0-30 s to
0-7,200 s.
•
Added Phase Toggle Delay setting for front panel HMI.
•
Added Off Mode Cooldown feature.
•
Added 51-3 element.
•
Added Var/PF control.
•
Added LSM Input settings.
•
Added Checksum Fail and CEM Hardware Mismatch pre-alarms.
•
Added kvar A, B, C, and Total metering.
•
Added several MTU items to metering.
•
Re-arranged CANbus Setup screens and added ECU Setup screens
on front panel HMI.
•
Added “P” (programmable) curve selection for the 51 function.
1.07.02, 09/08
•
Finalized settings for AEM-2020.
1.06.00, 07/08
•
Added settings for AEM-2020.
•
Added settings for Automatic Generator Detection.
•
Added settings for Integrating Reset on 51 function.
•
Added settings for Configurable Protection.
1.05.00, 04/08
•
Added settings for CEM-2020.
1.04.00, 12/07
•
Added settings for LSM-2020.
1.03.00, 08/07
•
Added 32 and 40Q protection functions.
•
Added Automatic Restart function and Exercise Timer.
•
Added dual settings for 51, 27, and 59 functions.
•
Added Oil Pressure Crank Disconnect Enable.
•
Modified Prestart operation during rest cycle.
•
Added 2 additional Engine kW Overload Pre-Alarms.
•
Added Low Line Scale Factor for EPS Supplying Load and Engine kW
Overload Pre-Alarms.
•
Changed the metering range of coolant temperature to 32-410 F.
•
Changed the Low-Coolant Temp Pre-Alarm range to 32-150 F.
1.02.00, 05/07
•
Added Spanish language support.
1.00.08, 03/07
•
Minor firmware improvements.
1.00.07, 01/07
•
Added Chinese language support.
xii
DGC-2020 Introduction