Register

Description

Type

Units

Scaling

Factor

R/W

Range

46600

AEM Input 7 Under 1
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46602

AEM Input 7Under 2
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46604

AEM Input 7 Over 1
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46606

AEM Input 7 Over 2
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46608

AEM Input 7 Under 1
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46610

AEM Input 7 Under 2
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46612

AEM Input 7 Out of
Range Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46614

AEM Input 8 Max
Voltage

Int32

DeciVolt

Deci

RW

0 - 100

46616

AEM Input 8 Max
Current

Int32

Milliamp x 10

Deci

RW

40 - 200

46618

AEM Input 8 Min
Voltage

Int32

DeciVolt

Deci

RW

0 - 100

46620

AEM Input 8 Min
Current

Int32

Milliamp x 10

Deci

RW

40 - 200

46622

AEM Input 8 Param Max

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46624

AEM Input 8 Param Min

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46626

AEM Input 8 Hysteresis

Int32

Deci Percent

Deci

RW

0 – 1000

46628

AEM Input 8 Arming
Delay

Int32

Second

N/A

RW

0 – 300

46630

AEM Input 8 Threshold
1 Activation Delay

Int32

Second

N/A

RW

0 – 300

46632

AEM Input 8 Threshold
2 Activation Delay

Int32

Second

N/A

RW

0 – 300

46634

AEM Input 8 Over 1
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46636

AEM Input 8Over 2
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46638

AEM Input 8 Under 1
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46640

AEM Input 8Under 2
Threshold

Int32

Centi Unit

Centi

RW

(-100000000) – 99999900

46642

AEM Input 8 Over 1
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46644

AEM Input 8 Over 2
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46646

AEM Input 8 Under 1
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only

46648

AEM Input 8 Under 2
Alarm Type

Int32

N/A

N/A

RW

0 = None
1 = Alarm
2 = Pre-Alarm
3 = Status Only