Single phase detect threshold, Start relay control, Run relay control – Basler Electric DGC-2020 User Manual

Page 454: Prestart relay control, Single phase connect generator detection, Off mode cool down enable, Reserved, Not in auto horn enable, Clock not set warning enable, Alternate frequency

background image

B-22

DGC-2020 Modbus

™ Communication

9400200990 Rev X

Register

Description

Type

Units

Scaling

Factor

R/W

Range

43642

Single Phase Detect Threshold

Int32

Volt

N/A

RW

0 - 480

43644

Start Relay Control

Uint32

N/A

N/A

RW

0 = Predefined
1 = Programmable

43646

Run Relay Control

Uint32

N/A

N/A

RW

0 = Predefined
1 = Programmable

43648

Prestart Relay Control

Uint32

N/A

N/A

RW

0 = Predefined
1 = Programmable

43650

Single Phase Connect
Generator Detection

Int32

N/A

N/A

RW

0 = A-B
1 = A-C

43652

Off Mode Cool Down Enable

Uint32

N/A

N/A

RW

0 = Disable
1 = Enable

43654

RESERVED

43656

Not In Auto Horn Enable

Uint32

N/A

N/A

RW

0 = Disable
1 = Enable

43658

Clock Not Set Warning Enable

Uint32

N/A

N/A

RW

0 = Disable
1 = Enable

43660

Alternate Frequency

Int32

Hertz

Centi

RW

1000 - 45000

43662

Generator System Type

Int32

N/A

N/A

RW

0 = Single Generator
1 = Multiple Generator

43664

Gen CT Low Line Scale Factor

Float

N/A

N/A

RW

0.001 - 3

43666

Metric Pressure Units

Int32

N/A

N/A

RW

0 = Bar
1 = kPa

43668

System Units

Int32

N/A

N/A

RW

0 = English
1 = Metric

43670

Kpa bar Config Data

Int32

N/A

N/A

RW

0 = Bar
1 = Kpa

43672

Crank Disconnect Pressure Bar
Data

Int32

Bar

Deci

RW

2 - 103

43674

RPM Bandwidth Data

Int32

N/A

N/A

RW

0 - 1000

43676

Number Flywheel Teeth

Uint32

N/A

Deci

RW

10 - 5000

43678

Phase Rotation

Int32

N/A

N/A

RW

0 = ACB
1 = ABC

43680

Restart Delay

Int32

Second

N/A

RW

0 - 120

43682

Configured Bus Connection

Uint32

N/A

N/A

RW

0 = Single Phase
1 = Three Phase

43684

Fuel Level Source

Int32

N/A

N/A

RW

1 – 9

43686

Fuel Level Percent Max

Int32

N/A

N/A

RW

0 – 150

43688

Fuel Level Percent Min

Int32

N/A

N/A

RW

0 – 150

43690

Cycle Rest Time

Uint32

Second

N/A

RW

5 - 15

43692

Rated Volts - Low Line Scale
Factor Data

Float

N/A

N/A

RW

0.001 - 3

43694-748

FUTURE USE

Control

Register

Description

Type

Units

Scaling Factor

R/W

Range

43750

Emergency Stop: Writing a 1 will
toggle emergency stop from off
to on. Writing a 1 again will
toggle emergency stop from on
to off

Int32

N/A

N/A

RW

1 = Toggle On/Off

43752

Remote Start

Int32

N/A

N/A

RW

0 = Disable
1 = Enable

43754

Remote Stop

Int32

N/A

N/A

RW

0 = Disable
1 = Enable

43756

Run Mode

Int32

N/A

N/A

RW

0 = Disable
1 = Enable

43758

Off Mode

Int32

N/A

N/A

RW

0 = Disable
1 = Enable

43760

Auto Mode

Int32

N/A

N/A

RW

0 = Disable
1 = Enable

43762

Alarm Reset

Int32

N/A

N/A

RW

0 = Disable
1 = Enable