beautypg.com

3 fit the control panel into position, Fit the control panel into position – Festo Кабели и принадлежности User Manual

Page 68

background image

2. Fitting

2−12

Festo P.BE−SPC200−EN en 0901d

2.3

Fit the control panel into position

Control panel type SPC200−MMI−1

Control panel type SPC200−MMI−1 can be inserted directly
into the diagnostic module type SPC200−MMI−DIAG of the
SPC200 (see Fig. 2/4).

Warning
Actuators can be activated unintentionally and the SPC200
can be damaged if modules are fitted or removed when
the power supply is switched on. Before carrying out inĆ
stallation and/or maintenance work, switch off the followĆ
ing in the sequence specified:

1. the compressed air supply

2. the load and operating voltage supplies on the SPC200

and, if applicable, the load voltage supply on the axis
interface string.

Proceed with fitting as follows:

Control panel type SPC200−MMI−1 can be inserted directly
into the diagnostic module type SPC200−MMI−DIAG of the
SPC200 (see Fig. 2/4).

1. Switch off the compressed air supply.

2. Switch off the load voltage and operating voltage supĆ

plies on the SPC200.

3. Carefully place the control panel onto the diagnostic

module type SPC200−MMI−DIAG of the SPC200. Make
sure that plug

3 and socket 5 are correctly aligned beĆ

fore fully inserting the control panel.

4. Make sure that locking pins

2 snap into position.