beautypg.com

3 record select mode, Record select mode – Festo Кабели и принадлежности User Manual

Page 203

background image

5. Controlling the SPC200

5−17

Festo P.BE−SPC200−EN en 0901d

5.3

Record Select mode

Record Select mode

In the Record Select mode the SPC200 is controlled by a
higher−order PLC/IPC. The controlling PLC/IPC sends posiĆ
tioning tasks in the form of binary−coded record numbers
via digital I/Os to the SPC200. The SPC200 then processes
the desired NC record and waits for the next positioning
task. If controlled by an I/O module, NC records 0...31 of the
starting programs can be accessed via 5 digital inputs. With
control via a field bus, the NC records 0...999 are available.

As the sequence of the NC programs is controlled by a higher−
order PLC/IPC, NC commands, which serve for sequence conĆ
trol, are not permitted in this operating mode.
Only the following NC commands are supported:

NC
command

Description

G00

Positioning at the highest possible speed

G01

Position at a defined speed

G02

Position with jerk−free acceleration
Position with Start/Stop frequency

G08

Acceleration for approach ramp

G09

Acceleration for braking ramp

G60

Exact stop

G61

Set positioning quality class

G62

Fast stop

G74

Start reference travel

G90

Absolute dimension specification
(pre−setting at program start)

G91

Relative dimension specification