3. Installation
3−46
Festo P.BE−SPC200−EN en 0901d
General connection assignment for I/O modules
without special control functions
The word number (here x) depends on the configuration of
the SPC200.
Configuration without
field bus module
Configuration with
field bus module
Word
number x
Second I/O module
First I/O module
2
Third I/O module
Second I/O module
4
Fourth I/O module
Third I/O module
5
Outputs without control function
Pin no.
Design.
1)
Address
2)
Start/Stop mode
Record Select mode
3)
1
0
Qx.0
Freely programmable
2
1
Qx.1
ć
3
2
Qx.2
ć
4
3
Qx.3
ć
5
4
Qx.4
ć
6
5
Qx.5
ć
7
6
Qx.6
ć
8
7
Qx.7
ć
9
24 V
ć
24 V external supply of outputs
10
0 V
ć
0 V external supply of outputs
1)
Designation on the module
2)
The word number (here x) depends on the configuration (Q = output).
3)
No freely programmable I/Os are supported in this operating mode.