Summary of record select mode – Festo Кабели и принадлежности User Manual
Page 211
5. Controlling the SPC200
5−25
Festo P.BE−SPC200−EN en 0901d
Summary of Record Select mode
The Record Select operating mode supports the close
coupling of the SPC200 with a higher−order PLC/IPC.
Record Select mode
Description
Prerequisites
Ĉ The program must already be saved in the program memory
Ĉ The system data must be entered in the configuration
Ĉ The Record Select mode must be set
Ĉ There must be a 1−signal at the ENABLE and STOP inputs
Operation with the control
panel
Operating functions
Ĉ Stop, Reset via menu SYSTEM CONTROL on the control panel
Operation via I/O
Operating functions
Select NC record via the RECBIT... inputs.
Ĉ Start the selected NC record via the CLK input
Ĉ Stop via the STOP input
Ĉ Program reset with 0−signal at the STOP input and rising edge
at the CLK input
Ĉ Fault acknowledgement with 1−signal at the STOP input and
rising edge at the CLK input