beautypg.com

Festo Кабели и принадлежности User Manual

Page 308

background image

7. Description of the commands

7−42

Festo P.BE−SPC200−EN en 0901d

G08

Acceleration for approach ramp and braking ramp

ć stepping motor axis; ć permitted in operating modes: Start/Stop, Record Select

Nn G08 X [Y.., Z.., U..]

tion>

n

Acceleration in %−steps of the configured maximum
acceleration; 0 = 100 %, 1 = 1 % ... 99 = 99 %

n = 0 ... 99

Rn

1)

Acceleration in %−steps of the configured maximum
acceleration saved in register Rn;
0 = 100 %, 1 = 1 % ... 99 = 99 %

n = 0 ... 99

@n

1)

Absolute value of the acceleration in [m/s

2

] or [10

3

°/s

2

]

saved in position register @n; permitted:
0.01

Ţ @n Ţ defined maximum acceleration

n = 0 ... 99

Effect

With the following command the stepping motor is moved and braked at maximum
with the acceleration specified here:
Ĉ G01

Example

N020 G08 X50 Y50

N021 G01 X80 FX50

N022 G08 X0

;Approach ramp and braking ramp = 50 %
;Move to position X80
;Approach ramp and braking ramp with
;maximum acceleration

The X−axis is accelerated and braked when approaching position X80 by only 50 %
of the configured maximum acceleration. The acceleration for the X−axis is then
switched to maximum acceleration.

Remark

This command has a saving effect. It remains effective until a new approach ramp
and braking ramp is defined.

1)

This syntax is only available as from operating system version 4.6. Programs which contain this
syntax cannot be edited with control panel type SPC200−MMI−1... .