Festo Кабели и принадлежности User Manual
Page 308
7. Description of the commands
7−42
Festo P.BE−SPC200−EN en 0901d
G08
Acceleration for approach ramp and braking ramp
ć stepping motor axis; ć permitted in operating modes: Start/Stop, Record Select
Nn G08 X
tion> n Acceleration in %−steps of the configured maximum n = 0 ... 99 Rn 1) Acceleration in %−steps of the configured maximum n = 0 ... 99 @n 1) Absolute value of the acceleration in [m/s 2 ] or [10 3 °/s 2 ] saved in position register @n; permitted: Ţ @n Ţ defined maximum acceleration n = 0 ... 99 Effect With the following command the stepping motor is moved and braked at maximum Example N020 G08 X50 Y50 N021 G01 X80 FX50 N022 G08 X0 ;Approach ramp and braking ramp = 50 % The X−axis is accelerated and braked when approaching position X80 by only 50 % Remark This command has a saving effect. It remains effective until a new approach ramp 1) This syntax is only available as from operating system version 4.6. Programs which contain this
acceleration; 0 = 100 %, 1 = 1 % ... 99 = 99 %
acceleration saved in register Rn;
0 = 100 %, 1 = 1 % ... 99 = 99 %
0.01
with the acceleration specified here:
Ĉ G01
;Move to position X80
;Approach ramp and braking ramp with
;maximum acceleration
of the configured maximum acceleration. The acceleration for the X−axis is then
switched to maximum acceleration.
and braking ramp is defined.
syntax cannot be edited with control panel type SPC200−MMI−1... .