C.1.3 start program or nc record, C.1.3, Start program or nc record – Festo Кабели и принадлежности User Manual
Page 455: Start nc program in start/stop mode
C. Technical appendix
C−9
Festo P.BE−SPC200−EN en 0901d
C.1.3
Start program or NC record
Prerequisites
Ĉ The program must already be saved in the program memory
Ĉ The axis, application and system data must be set correctly
Ĉ The operating mode must be set
Ĉ The SPC200 is ready to operate (1−signal at ENABLE and STOP
inputs and at READY output)
Start NC program in Start/Stop mode
In the operating mode Start/Stop the sequence is started or
continued with a rising signal edge at the START input. There
must be a 1−signal here at the STOP input.
If there is a 0−signal at the STOP input, a Program Reset will
be triggered by a rising edge at the START input.
Set START
Reset START
Wait 10 ms
Process NC program in
Start/Stop mode
Prepare new start
NC program will be started
Debounce time
End
Fig. C/5:
Start NC program in Start/Stop mode