beautypg.com

C.1.3 start program or nc record, C.1.3, Start program or nc record – Festo Кабели и принадлежности User Manual

Page 455: Start nc program in start/stop mode

background image

C. Technical appendix

C−9

Festo P.BE−SPC200−EN en 0901d

C.1.3

Start program or NC record

Prerequisites

Ĉ The program must already be saved in the program memory
Ĉ The axis, application and system data must be set correctly
Ĉ The operating mode must be set
Ĉ The SPC200 is ready to operate (1−signal at ENABLE and STOP

inputs and at READY output)

Start NC program in Start/Stop mode

In the operating mode Start/Stop the sequence is started or
continued with a rising signal edge at the START input. There
must be a 1−signal here at the STOP input.

If there is a 0−signal at the STOP input, a Program Reset will
be triggered by a rising edge at the START input.

Set START

Reset START

Wait 10 ms

Process NC program in
Start/Stop mode

Prepare new start

NC program will be started

Debounce time

End

Fig. C/5:

Start NC program in Start/Stop mode