beautypg.com

Festo Кабели и принадлежности User Manual

Page 457

background image

C. Technical appendix

C−11

Festo P.BE−SPC200−EN en 0901d

The following signal states must exist at the control inputs
before the readiness to operate can be created:

Record Select mode

Control input

Signal

ENABLE

1−signal

STOP

When acknowledging with the RESET signal:
0−signal
When acknowledging with the CLK signal:
1−signal

RESET

0−signal

CLK_B

0−signal

CLK_A

0−signal

Tab. C/1:

Necessary signal states in Record Select mode

Start/Stop mode

Control input

Signal

ENABLE

1−signal

STOP

1−Signal

*)

START/RESET

0−signal

SYNC_IB

not relevant

SYNC_IA

not relevant

*)

If there is a 0−signal at the STOP input, a Program Reset will be
triggered by a rising edge at the START/RESET input.

Tab. C/2:

Necessary signal states in Start/Stop mode