Festo Кабели и принадлежности User Manual
Page 457
C. Technical appendix
C−11
Festo P.BE−SPC200−EN en 0901d
The following signal states must exist at the control inputs
before the readiness to operate can be created:
Record Select mode
Control input
Signal
ENABLE
1−signal
STOP
When acknowledging with the RESET signal:
0−signal
When acknowledging with the CLK signal:
1−signal
RESET
0−signal
CLK_B
0−signal
CLK_A
0−signal
Tab. C/1:
Necessary signal states in Record Select mode
Start/Stop mode
Control input
Signal
ENABLE
1−signal
STOP
1−Signal
*)
START/RESET
0−signal
SYNC_IB
not relevant
SYNC_IA
not relevant
*)
If there is a 0−signal at the STOP input, a Program Reset will be
triggered by a rising edge at the START/RESET input.
Tab. C/2:
Necessary signal states in Start/Stop mode