4. Commissioning
4−34
Festo P.BE−SPC200−EN en 0901d
Carry out identification travel as follows:
1. Make sure that the tubing of the positioning system is
correctly connected (see step 2, movement test).
2. Set the compressed air supply to the pressure desired
during operation. Standard setting = 6 bar.
3. Select the submenu AXIS in the menu TEST/DIAG. and
press the Enter button.
TEST/DIAG. AXIS
X:
4. The cursor is positioned on the axis identifier. Select the
desired axis with the buttons
vV (here X) and press the
Enter button. The first command in the submenu AXIS will
then be displayed.
TEST/DIAG. AXIS
JOG AXIS >
5. Select the command IDENTIFICATION with the buttons
{ }.
TEST/DIAG. AXIS
IDENTIFICATION >
6. Press the Enter button in order to select the command.
IDENTIFICATION
X: STATIC?
7. Select the identification travel which you wish to carry out
with
vV. Meaning: