beautypg.com

Festo Кабели и принадлежности User Manual

Page 178

background image

4. Commissioning

4−34

Festo P.BE−SPC200−EN en 0901d

Carry out identification travel as follows:

1. Make sure that the tubing of the positioning system is

correctly connected (see step 2, movement test).

2. Set the compressed air supply to the pressure desired

during operation. Standard setting = 6 bar.

3. Select the submenu AXIS in the menu TEST/DIAG. and

press the Enter button.

TEST/DIAG. AXIS

X:

4. The cursor is positioned on the axis identifier. Select the

desired axis with the buttons

vV (here X) and press the

Enter button. The first command in the submenu AXIS will
then be displayed.

TEST/DIAG. AXIS

JOG AXIS >

5. Select the command IDENTIFICATION with the buttons

{ }.

TEST/DIAG. AXIS

IDENTIFICATION >

6. Press the Enter button in order to select the command.

IDENTIFICATION

X: STATIC?

7. Select the identification travel which you wish to carry out

with

vV. Meaning: