3. Installation
3−43
Festo P.BE−SPC200−EN en 0901d
Connection assignment of front plug X5 for the first
I/O module when operated without a field bus
module
If a field bus module is not installed, the first I/O module will
provide the following control inputs:
Inputs with control function
Pin no.
Design.
1)
Address
2)
Start/Stop mode
Record Select mode
1
24 V
ć
24 V sensor supply (not with separate potential)
2
0 V
ć
0 V (not with separate potential)
3
0
I0.0
Freely programmable
RECBIT1
4
1
I0.1
RECBIT2
5
2
I0.2
RECBIT3
6
3
I0.3
RECBIT4
7
4
I0.4
RECBIT5
8
5
I0.5
SYNC_IB
CLK_B
9
6
I0.6
SYNC_IA
CLK_A
10
7
I0.7
STOP
STOP
11
8
I0.8
START/RESET
3)
RESET
3)
12
9
I0.9
ENABLE
ENABLE
1)
Designation on the module
2)
Addresses of the first installed I/O module when configured without a field bus module (I = input)
3)
RESET (Program Reset) in conjunction with 0−signal at the STOP input