beautypg.com

Festo Кабели и принадлежности User Manual

Page 63

background image

2. Fitting

2−7

Festo P.BE−SPC200−EN en 0901d

Warning
Actuators can be activated unintentionally and the SPC200
can be damaged if modules are fitted or removed when
the power supply is switched on. Before carrying out inĆ
stallation and/or maintenance work, switch off the followĆ
ing in the sequence specified:

1. the compressed air supply

2. the load voltage and operating voltage supplies of the

SPC200.

Fitting modules

Fit the modules into the rack as follows:

1. Switch off the compressed air supply and the operating

voltage supply.

2. If necessary, remove the blanking plate.

3. Hold the module by the front plate and push it into the

guide rail. Make sure that the modules are not tilted
when they are pushed in and that the components on the
printed circuit board are not damaged.

4. Make sure that the plugs on the contact strips are corĆ

rectly aligned. Then gently push the module in comĆ
pletely. The locking levers will then engage automatically
(see Fig. 2/1).