4. Commissioning
4−21
Festo P.BE−SPC200−EN en 0901d
4.3.4
Application data of an electric stepping motor axis
The application data describe the general conditions under
which the positioning axis is operated:
Application data
Unit
Default values
Example
Resolution for a full step [1/1]
1)
mm
−1
5.00000
8.00000
Step mode
2)
ć
1/2
1/1
Resolution
3)
mm
−1
10.00000
8.00000
Start−stop frequency
Hz
400
400
Project zero point
mm
0.00
0.00
Lower software end position
mm
10.00
10.00
Upper software end position
mm
90.00
490.00
Reference position
mm
10.00
10.00
Reference speed factor
ć
0.5
1.0
Maximum speed
m/s
0.10
1.0
Maximum acceleration
m/s
2
0.50
2.0
Reference run mode
1)
ć
1
1
1)
Corresponds to Resolution" on the control panel
2)
Only limited availability via control panel
3)