beautypg.com

Festo Кабели и принадлежности User Manual

Page 165

background image

4. Commissioning

4−21

Festo P.BE−SPC200−EN en 0901d

4.3.4

Application data of an electric stepping motor axis

The application data describe the general conditions under
which the positioning axis is operated:

Application data

Unit

Default values

Example

Resolution for a full step [1/1]

1)

mm

−1

5.00000

8.00000

Step mode

2)

ć

1/2

1/1

Resolution

3)

mm

−1

10.00000

8.00000

Start−stop frequency

Hz

400

400

Project zero point

mm

0.00

0.00

Lower software end position

mm

10.00

10.00

Upper software end position

mm

90.00

490.00

Reference position

mm

10.00

10.00

Reference speed factor

ć

0.5

1.0

Maximum speed

m/s

0.10

1.0

Maximum acceleration

m/s

2

0.50

2.0

Reference run mode

1)

ć

1

1

1)

Corresponds to Resolution" on the control panel

2)

Only limited availability via control panel

3)

Operand = resolution for full step divided by the step mode